VACUUM IMPREGNATION PLANT
|
| TECHNICAL SPECIFICATIONS
|
IMPREGNATION CYCLE Vacuum / Pressure Impregnation Plant is designed for varnish impregnation to be carried out in following steps and will be generally as per the schematic diagram attached.
1. Pre-heating the jobs in either Impregnation Chamber or Oven.
2. Evacuation of Impregnation Chamber (after putting the jobs) to make the voids in the jobs clear
and drying of jobs for specific time & required temperature / vacuum.
3. Induction of impregnant (Varnish) in the Impregnation Chamber from impregnant Tank to submerge
the jobs in it.
4. Pressurize the Impregnation Chamber with dry air or nitrogen to fill the voids with impregnant.
5. Return the varnish to impregnant Tank.
6. Evacuate the Impregnation Chamber and cure the jobs either in impregnation Chamber or in
Oven for specific time.
MAJOR COMPONENTS
IMPREGNATION CHAMBER
· Working Volume: 100 Ltrs to 5000 Ltrs.
· Material of construction: M.S. plates, bars, structural etc.
· Working Pressure: @ 4 kg/ cm2 & Vacuum: As per process requirement.
· Lid Opening: Screw Davit type for quick opening & closing.
· Chamber Dimensions: as per job Size and Quantity.
· Will be provided with: Oil Heating / cooling Jacket, Quick Clamping bolts, Stirrer, Neoprene Gaskets,
Sight glass, Illuminating Lamp, Pressure Safety Valve, Vacuum & Pressure gauges etc. as per the
varnish specifications.
IMPREGNANT STORAGE TANK
¨ Material of Construction: M.S. plates, bars, structural etc.
¨ Will be provided with: Level Indicator, Motorised Stirrer, Thermometer & Thermostat to control the
varnish temperature, Return Line Filter to prevent entry of impurities carried away from impregnation
chamber to storage tank and suitable drain. Silica Gel Breather will also be provided to prevent
absorption of atmospheric moisture.
¨ Chamber Dimensions: as per job Size and Quantity.
VACUUM / PRESSURE PUMP
· Type: Rotary Oil sealed Vacuum Pump.
· Capacity (free air displacement): As per cycle requirement
· Make: Acmevac Make
· Working Vacuum - As per the process requirement.
IMPREGNANT TRANSFER SYSTEM
1. Inter-connecting pipes: M. S. ERW, B Class.
2. Valves: Piston Type (Vacuum tight with O'rings & Nylon wipers)
3. Connections: Flanged type with Neoprene O'rings.
4. Operating Platform: M.S. Fabricated suitable for easy plant operation in case of big plants.
CONTROL PANEL
Centralized Control panel for easy and safe operation will be provided
along with necessary gauges and controls.
|
|
|